  • Model Number:

    TMAX-GBP
  • Dimension(L*W*H):

    600*529*700mm
  • Compliance:

    CE Certified
  • Warranty:

    One year limited warranty with lifetime support
  • MOQ:

    1
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days
Product Details

2 to 4 Port Glove Box with a Gas Purification System



Purification Glove Box

We accept customers' special requirements such as special materials, special sizes, and special shapes. Professional customization is available as you wish.

A: Product Introduction

   The glove box is specially designed for research in materials science, chemistry, semiconductor and related industries. It uses German BASF deoxygenating materials and American UOP highly efficient water-absorbing materials. The water and oxygen components inside the glove box can maintain the gas purity at 1 ppm or below for a long time. Product application

In chemical reactions and the handling of test samples, some substances are sensitive to oxygen and water and cannot be processed under normal natural conditions. Using a glove box enables these substances to react and be tested in an inert gas environment that is relatively oxygen-free and water-free. It is widely applied in: lithium-ion batteries and materials, semiconductors, thin film preparation, nanomaterials, catalysts, super capacitors, special lamps, laser welding, brazing, titanium alloy welding, etc.

B: Product functions

Air pressure of the manual/automatic control system;

Purification status of the manual/automatic control system;

Reduction process of the automatic gas purification system;

Automatic prompt and alarm function;

System control parameter setting;

System parameter recording;

Condition detection of the system's actuator.

C: Product Specifications

1. Box resistance to pressure: ±3000 Pa

2. Water content in the box under standard conditions: ≤ 1 ppm (Note: Standard conditions refer to one atmosphere pressure and a constant temperature of 20 degrees Celsius)

3. Oxygen content in the box under standard conditions: ≤ 1 ppm (Note: Standard conditions refer to one atmosphere pressure and a constant temperature of 20 degrees Celsius)

4. Leakage rate: ≤ 0.05 Vol% per hour (checked by the change in oxygen content in the box)

5. Used gases:

a) Working gas: N2, Ar, He, etc.

b) Control gas: The working gas used during operation (N2, Ar, He, etc.)

c) Reduction gas: A mixture of the working gas and hydrogen (H2).

Purification Glove Box 

D: Product Parameter

Instructions of Model No. Of Glove Box With Purification System

Purification Glove Box 

Quantity of Gloves: 2, 3, 4, 6, 8 gloves are available.
S/D: D indicates double-side operationS indicates single operation
800: 800 indicates width of the box bottom, unit: mm
GBP: GBP is abbreviation of Glove Box With Purification System

 

Specifications of Standard Model of Purification Glove Box

No.

Model No.

Box Dimensions

Total Dimensions

Operating Sides

Numbers of Gloves

Options

 

1

TMAX-GBP800-2

1200*800*930mm

1915*830*1830mm

Single

2

Single or double purification columns

2

TMAX-GBP1000S-2

1200*1000*930mm

1915*1060*1830mm

Single

2

Single or double purification columns

3

TMAX-GBP1000D-4

1200*1000*930mm

1915*1060*1830mm

Double

4

Single or double purification columns

4

TMAX-GBP1200S-2

1200*1200*930mm

1915*1260*1830mm

Single

2

Single or double purification columns

5

TMAX-GBP1200D-4

1200*1200*930mm

1915*1260*1830mm

Double

4

Single or double purification columns

 

 

6

TMAX-GBP800-3

1500*800*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

7

TMAX-GBP1000S-3

1500*1000*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

8

TMAX-GBP1000D-6

1500*1000*930mm

2215*1060*1830mm

Double

6

Single or double purification columns

9

TMAX-GBP1200S-3

1500*1200*930mm

2215*1260*1830mm

Single

3

Single or double purification columns

10

TMAX-GBP1200D-6

1500*1200*930mm

2215*1260*1830mm

Double

6

Single or double purification columns

 

 

11

TMAX-GBP800-4

1900*800*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

12

TMAX-GBP1000S-4

1900*1000*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

13

TMAX-GBP1000D-8

1900*1000*930mm

2615*1060*1830mm

Double

8

Single or double purification columns

14

TMAX-GBP1200S-4

1900*1200*930mm

2615*1260*1830mm

Single

4

Single or double purification columns

15

TMAX-GBP1200D-8

1900*1200*930mm

2615*1260*1830mm

Double

8

Single or double purification columns

 

Notes
Cabinet water and oxygen content under the standard condition:  
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gases
a) Working Gas: N2ArHe and etc.
b) Controlling Gas: Compressed air or Inert Gas.
c) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements

 

Technical Index of Purification Glove Box

Gas pressure withstand by the box body

 -3000Pa -+3000Pa

The vacuum degree value that the transition chamber can withstand

<100pa

Cabinet water content in the standard condition (Note: The standard condition is one atmospheric pressure, constant temperature of 20 degrees) 

<1ppm

Cabinet oxygen content in the standard condition (The standard condition is one atmospheric pressure, constant temperature of 20 degrees )

<1ppm

Leakage rate

<0.05vol%/h


Function of Purification Glove Box

NAME

DESCRIPTION

Automatic control

Controlled and monitored automatically by the program control unit.

Box body manual/auto gas replacement

Before initial use, cabinet air shall be "replaced" with inert gas or nitrogen, which can be easily achieved by using auto gas replacement function of the cabinet provided by the system, gas replacement can also be achieved manually.

Transition cabinet manual/auto replacement

 When material was placed in a box, the transition cabinet of the gas needs to be replaced. You may automatic gas exchange function provided by the airlock system; you may also achieve gas replacement manually. 

Gas purification control

After setting up the work status and results, the system purification procedures set to “Auto”, the system will automatically maintain the atmosphere condition of the cabinets, then the system will automatically complete the work; you may also choose to manual control.

Pedal air-pressure control

Use the foot controller-through inflation or exhaust system, to control gas pressure in the cabinets.

Reduction of purification system

Purification materials restore is done automatically by the system, we only need to set the conditions of system restore. Open “restore”, the system will automatically complete the restoration work, the whole process does not need to monitor. 

On-line operating condition detection

The control system provides users with the operating condition detection function of the component of the equipment. Such function can be used to observe operating condition of the component and inspect fault source of each function and component.

System parameter setting

System settings function, users can set the system parameters to achieve the desired working conditions and feature set.

Data logging function

The system provides operating parameter record of the equipment, this record can be traced back to monitor production or experiment.

Control of gas reserve function

When the temporary cutting of control-gas supply, or cutting off control-gas source for some time, the control-gas reserve will protect the equipment continue working.

Standby function of cycle gas cooled

Purification system provides a heat exchange for cooling the circulating gas, can be used alone by injecting the coolant to control the temperature of the circulating gas.

Multi-level safety system

The control system sets up a variety of security features, include multilevel security tips, alarm and disable function, to protect the safety of operating personnel and equipment.

Protection function when purification cycle blocked

When the circulation system is blocked, the control system prompts alerts, and take the initiative to adjust the speed of air, in order to protect the motor, though this function can also check out system cycle blocked, pipeline poor, filter control dust obstruction, and other issues.

Option of glove box with purification system

Data recording and printing; Remote service functions; System temperature control function

 

 

Accessories and quantity

technical specification

remark

1 standard transition chamber

Dn385×588mm

 

Located on the right side of the box, material: SUS304 stainless steel; Aluminum alloy door cover with movable drawers inside. Configure the door opening assist device

1 tool transition compartment

DN150×350mm

 

It is located on the right side of the box, made of SUS304 stainless steel

1 shelving unit

three layers

Back-hanging style

1 box frame

900mm in height

It is equipped with universal casters, making it convenient to move the glove box. The right section of the rack is integrated with a purification system inside

Transparent and visible panel

Thickness: 12mm

It adopts double-layer laminated tempered glass with a protective film attached inside (to prevent electrolyte corrosion).

4 pairs of gloves

Thickness: 0.4mm

Butyl

1 power socket

220V, 10A, 8-pin connector

Located inside the box

Illuminating system

Brand: Philips

Configure fluorescent tubes

3 sets of spare interfaces

KF40

 

Material: SUS304 stainless steel: Equipped with quick-installation couplings

1 vacuum pump

Model: D16C

Pumping capacity: 4L/S, brand: Imported brand, equipped with oil mist filter

2 HEPA filters

Filtration accuracy: 0.3 μ m

Installed inside the box, it filters dust and keeps the ventilation pipeline unobstructed

2 vacuum gauges

Mechanical dial display

Measure the vacuum degree of the transition chamber and the tool transition chamber

1 pressure gauge

Mechanical dial display

Measure the air pressure of the box

1 foot pedal controller

Double tread plate

The gas replenishment and venting of the control box

Control system

Color touch screen: 6 inches

Touch screen, PLC brand: SIEMENS (The touch screen is hung on the box and can rotate freely) The operation interface in Chinese, English and Russian can be switched freely.

1 pressure sensor

-2500 to 2500Pa (relative pressure)

Touch screen display

1 water analyzer

0~1000ppm

Touch screen display

accuracy: 0.1ppm, brand: imported brand

1 oxygen transmitter

0~1000ppm

Touch screen display

accuracy: 0.1ppm, ZrO2 oxygen sensing

Gas purge system

Single purification column

Has the functions of dehydrating and deoxygenating; Integrated onto the box frame;

Dehydration material: Imported brand

Deoxygenation material: Imported brand

Organic solvent adsorption system

21L

 

Installed on the glove box pipeline

1 USB interface

Customization

Backup

1 set of Ethernet cable interface

Customization

Backup

5 sets of spare electrical interfaces

Core count: 4×1.0

Backup