Discharging Testing Machine

30V 10A Charge 10A Discharge 40 Channel Battery Pack Testing Equipment&Aging Cabinet with Energy-Saving Function

  • Model Number:

    TMAX-BCDS30V10A
  • Input Power:

    ≤12KW
  • Dimension(L*W*H):

    1300*600*1840mm(W*D*H )
  • Compliance:

    CE Certified
  • Warranty:

    Two years limited warranty with lifetime technical support
  • Place of Origin:

    China
  • Update:

    Optional
  • Shipping Port:

    Xiamen Port
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days

products categories

contact us

Product Details
 30V 10A Charge 10A Discharge 40 Channel Battery Pack Testing Equipment&Aging Cabinet with Energy-Saving Function

 

 

I. Equipment Principle and Composition


1.1 Host Computer: The host computer software serves as the primary human-machine interaction tool, enabling functions such as device startup, shutdown, pause, and resumption. The host computer is responsible for collecting and processing battery aging data, and outputs the test results required by the client.

1.2 Central Control Unit (CCU): The CCU serves as the central control management software for the device, performing calculations on battery parameters such as capacity and charge level.

1.3 Bidirectional ACDC+LLC Isolated DCDC: During charging, this module draws power from the grid, which is then regulated by the bidirectional DCDC to charge the battery. During discharging, it feeds back the energy transmitted by the bidirectional DCDC to the grid.

1.4 Bidirectional DCDC (Buck/Boost): This non-isolated DCDC module provides all required current and voltage outputs for battery charging and discharging, including constant current charging, constant voltage charging, and constant current discharging.

II. Scope of Application

The system is designed for integrated cycle testing of lithium battery packs, including charging, discharging, functional testing, and data monitoring, and is applied to electric tools, solar energy storage, toy cars, scooters, electric bicycles, electric motorcycles, and home energy storage systems.

III. Equipment Environmental Requirements and Technical Parameters

3.1 Full-unit power supply: AC voltage 380V ±10%, frequency 50Hz ±10%.

3.2 Ambient temperature: -10 to 45°C;

3.3 The environment is free from strong vibrations, corrosive gases, and flammable or explosive gases.

IV. Feature Introduction

4.1 Charging and Discharging Functions: Features constant current and constant voltage charging, constant current discharging, and battery capacity recording during charging and discharging processes.

4.2 Voltage protection test: Verify the battery's charge and discharge protection functions by performing charge and discharge cycles.

4.3 Safety Protection: Features include anti-reverse connection protection, power failure data protection, support for continuous testing, voltage upper/lower limit setting protection, and safe discharge current protection.

4.4 The system employs high-frequency isolation technology to maintain complete separation from the power grid, ensuring safe and stable operation.

4.5 The bidirectional AC/DC module employs space vector modulation technology with digital control, achieving high voltage utilization efficiency and reduced current harmonic diversion.

4.6 Enables internal conversion of dual-channel charge-discharge energy;

4.7 The DCDC module employs advanced PID control technology and multiple protection mechanisms to ensure stable operation of the equipment.

4.8 Energy Recycling (DC Busbar Efficiency 93%): This system enables energy recycling, allowing battery discharge energy to be fed back into the grid.

4.9 Seamless switching between constant current and constant voltage modes without any voltage/current surges, effectively preventing battery tab debinding caused by heat accumulation from peak currents.

4.10 The voltage and current are sampled using a four-wire system, which ensures high sampling accuracy and excellent long-term stability.

4.11 Supports barcode input for batteries, with traceable historical test data.

V. Equipment Parameter Description

Product model

TMAX-BCDS30V10A

AC input interface

1. Input three-phase five-wire AC380V

2. Input current: 22A; recommended circuit breaker: 32A-3P or higher           

3. Frequency: 50Hz             

4. THD3%             

5. Power factor> 0.99 (rated power)

6. Charging efficiency: 88% (whole device)                  

7. The bus feedback efficiency is 93%.

System function

1. Battery Cycle Life Testing                          

2. Battery Capacity Test                                                   

3. Battery Charge/Discharge Characteristic Test

4. Battery Charge Retention Capability Test                                

5. Battery Charge/Discharge Efficiency Test                                     

6. Battery Overcharge/Overdischarge Rate Tolerance Test

Voltage

Measuring range

4.5~30V (using 2 or more battery strings)

Accuracy

±0.1% of F.S±0.1% of F.D

Current

Charging range

0.1-10A

Discharge range

0.1-10A

Accuracy

±0.1% of F.S±0.1% of F.D

Charge

Constant voltage cutoff current

Minimum 50mA

Capacity

Accuracy

±0.1% of F.S±0.1% of F.D

Power

Maximum power per cabinet

12KW

Current response time

Current hardware response time:

20ms

Data recording interval

1S

Data export method

The data can be exported to Excel or chart files, providing various data analysis formats such as charge-discharge curves, capacity decay rate, cycle life curves, charge-discharge voltage, current, and capacity-time curves, along with data lists.

Data save mode

Users can customize names and data save paths. Data is saved as files.

Primary channel mode

Charging modes: Constant Current Charging (CC), Constant Voltage Charging (CV), and Constant Current & Voltage Charging (CCCV)

Discharge: Constant Current Discharge (CD), Constant Current and Constant Voltage Discharge (CVD)

Communication mode

LAN(TCP/IP)

Test data record

Voltage, Current, Time, Capacity, Power

Input protection

overvoltage, overcurrent, phase loss, overtemperature, protection alarm, island effect protection;

Output protection

No output when overvoltage, overcurrent, short circuit, reverse connection, capacity, temperature, or battery voltage is detected.

Software protection

Power-off data protection, call continuation, overvoltage/overdischarge protection, overcurrent/undercurrent protection, capacity protection, overtemperature protection, voltage trend anomaly protection, current trend anomaly protection, current fluctuation anomaly protection, voltage fluctuation anomaly protection, charging voltage rise rate anomaly protection, discharge current decline rate anomaly protection;

Cycle index

Up to 10,000 times

Cooling-down method

air blast cooling


VI. Product Appearance and Structure


Rack size

1300*600*1840mmW*D*H

Number of channels

40 channel

Device accessories

Test sheet, online tools, user manual, host software

The image above is for reference only. Please refer to the actual product.


VII. Software and Interface Introduction

7.1 Main Interface


7.2 Plan Setup Interface


7.3 Test Curve Interface


7.4 Detailed Data Interface


VIII. Main Configuration List

No.

Name

Brand

Quantity

Unit

1

Main control panel

In-house

20

block

2

Host CPU

TI America  

20

individual

3

Communication module

In-house

1

individual

4

Electric relay

Honfa

160

individual

5

Source

Lorenz/Photo

Power selection

individual

6

Leakage circuit breaker

Chint

1

individual

7

Cabinet

In-house

1

individual

8

Software system

In-house

1

cover


IX. Randomized List of Materials

No.

Accessory name

Quantity

1

Testing facility

1 unit

2

Charge and discharge test harness

40 pcs

3

Communication accessories

a surname

4

Test software system

1 set

5

User Manual

1 copy

6

Product Qualification Certificate  (including  Calibration Certificate)

1 copy

Note: Customers must provide their own computers for testing software, and technical staff will guide the software installation and provide training.


There are some other aging cabinets for options: 30V 5A 100 channels /20V10A 100 channels/ 30V 10A 100 channels/ 30V 20A 40 channels/ 30V 20A 100 channels/ 100V 10A 50 channels/ 60V 20A 50 channels/ 100V 20A 30 channels/ 60V 30A 30 channels; The above is an aging machine with a battery rack.


60V 50A(100V 30A) 30 channels/ 20 channels/ 10 channels/ 

100V 50A 18 channels/ 12 channels/ 6 channels/ 

100V 60A(60V 100A) 18 channels/ 12 channels/ 6 channels/

100V 100A 12 channels/ 6 channels 

100V 120A(120V 100A) 12 channels/ 8 channels/ 4 channels/ 

100V 150A 8 channels/ 4 channels