Charging Discharging Tester

5V 6A 512 Channel Li-ion Cylindrical Cell Charging and Discharging Testing Machine Battery Range Tester

  • Model Number:

    TMAX-XL6512LK-5V6A
  • Dimension(L*W*H):

    1550mm (W) × 500mm (L) × 1850mm (H)
  • Compliance:

    CE Certified
  • Warranty:

    2 Year limited warranty with lifetime support
  • Place of Origin:

    China
  • Shipping Port:

    Xiamen
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    5 days

products categories

contact us

Product Details

5V 6A 512 Channel Li-ion Cylindrical Cell Charging and Discharging Testing Machine Battery Range Tester

 

 

I. Equipment Configuration List

No.

Category

Product Name

Model

Quantity

Remark

1

Cell Grading Equipment

Feedback Formation Device

TMAX-XL6512LK-5V6A

1 set

512CH 5V 6A

2

Accessories

Communication Accessories

Communication cables /

RJ45 plugs, etc.

Several

Suitable for on-site connection

 

II. Equipment Scope and Function

l Scope of application: Mainly used for cell grading, suitable for specific types of cells (cylindrical 18650 -32700).

l Supported tests: Constant current charge, constant current-constant voltage charge, constant current discharge, rest, etc.

 

III. Process Flow Diagram

Manual loading Send process step Process completion Manual unloading

 

IV. Incoming Material Specifications and Compatibility

Applicable cells: Diameter 1832 mm, height 5070 mm

 

V. Equipment Description

l Open-frame structure with four doors, 8 layers each, totaling 32 fixture trays.

l Each tray holds 16 cells (16 channels), totaling 512 channels.

l The equipment contacts the positive and negative poles of the cells for charge/discharge testing.

l Device size: 1550mm(L)*500mm(W)*1850mm(H)

 

VI. Environmental Requirements

l Power supply: AC 380V ±10%, 50Hz ±5%, max cabinet input power: 20KW (512CH)

l Ambient temperature: 040°C

l Ambient humidity: 75% R.H (no condensation)

l Environment: No strong vibration, no corrosive or flammable/explosive gases

l ESD protection: Grounding required with independent grounding port

 

VII. Technical Parameters

No.

Parameter

TMAX-XL6512LK-5V6A (512CH)

1

Channel Control Mode

Whole machine start

2

Voltage

Charge: 10 mV–5000 mV; Accuracy: ±(0.05%RD+0.05%FS); Resolution: 1 mV; Minimum discharge voltage: 2000 mV

3

Current

Charge: 30 mA–6000 mA; Discharge: -30 mA–-6000 mA; Accuracy: ±(0.05%RD+0.05%FS); Resolution: 1 mA

4

Time

Step time: 1–1000 min/step, Accuracy: ±0.1%

5

Data

Interval: 1–999 min; ΔU: 10 mV; ΔI: 10 mA; Statistics: OCV, average voltage, working time, current, capacity per step; detailed curve and data; cell count per capacity range

6

Charge

Modes: CC, CC-CV; Cutoff conditions: voltage, current, relative time, capacity

7

Discharge

Mode: CC; Cutoff conditions: voltage, current, relative time, capacity

8

Cycle

Measurement range: 1–32 cycles; Steps per cycle: 16

9

Curve Display

Current, voltage, capacity curves

10

Protection

Software protection, power-off data protection; Configurable safety limits (voltage, current, capacity); Hardware: reverse connection protection module

11

Voltage & Current Sampling

Four-wire connection

12

Noise

<75 dB at 1 m distance

13

PC Communication

Ethernet

14

Data Output

Excel, PDF, Graphs

15

Communication Interface

CAN

16

Current Accuracy Temp Range

25±3°C

17

Current Calibration

Using calibration fixture; Calibration cycle: 12 months

18

Sorting Function

Yes, LED hardware display and software-based sorting

19

Inspection Speed

3 s

20

Fault Rate

≤2%

21

Optimal Charge Efficiency

≥70% (DC-DC port)

22

Optimal Discharge Feedback Efficiency

≥60% (DC-DC port)

23

Offline Protection

Pauses testing when communication interrupted; resumes after user confirmation

25

Appearance

International standard warm gray 1C


VIII. Equipment Appearance