products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13003860308
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
products
60V40A Battery Tester

60V40A 1 Channel Battery Tester for the Power Battery/Prismatic Battery/ Battery Pack Testing

  • Model Number:

    TMAX-BTS-60V40A
  • Dimension(L*W*H):

    Cutomized
  • Compliance:

    CE Certified
  • Warranty:

    One years limited warranty with lifetime technical support
  • Place of Origin:

    China
  • MOQ:

    1
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    30 days
Product Details

60V40A 1 Channel Battery Tester for the Power Battery/Prismatic Battery/ Battery Pack Testing

System Features

1.Single point independent, independent charging and discharging steps can be set for each battery test channel.

2.The accuracy of the equipment is 0.05%, the data recording time is 1 s / time, the fastest is 0.1 s / time, and the stability is high.

3.The software has powerful function and friendly man-machine interface.

4.Four wire test interface ensures high measurement accuracy.

5.Modular design concept, easy to maintain.


Equipment Description

TMAX high precision battery test system is mainly designed for power battery / battery pack, which can meet  the performance test requirements of power battery pack. The equipment has the characteristics of high power, high precision and high performance. It can charge the equipment voltage from 0 to 60 V and discharge from 60V to 5V, and charge and discharge test and capacity division of batteries with various specifications from 0 to 40A.


Device View

View size of single table (external dimension: length * width * height = 800 * 650 * 178mm)



 View dimension of the whole cabinet (external dimension: L * w * H = 790*950*1806mm)

Product Specification

Equipment model

UPC60V40A-01NC

Number of output channels of equipment model

1CH (1 channel per device)

Communication mode

RJ45(Network port)

Charging voltage

DC 0 ~ 60V charging can be used to detect and set the voltage range, the maximum voltage is 60V

Discharge voltage

DC 60 ~ 5V discharge can be used to detect and set the voltage range, the maximum voltage is 60V

Charging current

DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A

Discharge current

DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A

Voltage accuracy

±0.05%RD + 0.05%FS

Current accuracy

±0.05%RD + 0.05%FS

Voltage resolution

1mVThe minimum unit used by a device to detect or set voltage

Voltage stability

≤0.05%

Current resolution

1mAThe minimum unit used by a device to detect or set current

Current stability

≤0.05%

Power output range

0.5Pmax = Vmax * Imax

Input impedance

≧10 MΩ

Input power

AC 220 V ± 10% / 50 Hz (cabinet power supply mode: three phase five wire)

Power accuracy

±0.05%RD + 0.05%FS

Current response time

When the current output is 40A, the hardware response time is as follows:≤50ms

Time setting range

Any setting within 0-9999 minutes, the time units are h, min and s, and the resolution is 0.1s

Time accuracy

≤±0.1%

Recording method

Charging recording time, discharging recording time, static recording time and global recording time

Recording frequency

100mS65535S

Sampling frequency

About 10ms per box

Charging mode

Constant current and voltage limiting, constant current and constant voltage, constant power charging, constant flow charging test (battery with protection board)

Charging cut-off conditions

Voltage, current, time, capacity, temperature

Discharge mode

Constant current and constant power discharge (battery with protection board)

Discharge cut-off conditions

Voltage, current, time, capacity, temperature

Protection function

Data abnormal recovery; battery reverse connection protection function;

Software over-voltage, under voltage, over-current, under current and over capacity protection. The range of voltage and current protection value can be set, and prompt and record after protection;

Number of single cycle work steps

≤100 steps, with nested loop function

Continuous working hours

The power of the equipment shall meet the requirements of full load and 365 * 24-hour uninterrupted operation of all channels

Equipment noise

Less than 60dB

Circuit structure

Modular structure design, easy to replace and maintain

VCELLTCELL

Auxiliary temperature and voltage can be selected and 16 channels in single box can be selected

 

 

 

 

 

 

 

Software

The software supports various kinds of connection, such as manual suspension connection, software shutdown connection, power interruption connection, equipment communication interruption connection and abnormal stop connection;

It supports barcode scanning, and can scan one-dimensional code and two-dimensional code. There are scanning methods such as sequential scanning, channel skipping scanning, loading and disk scanning;

Local test detailed data storage, you can view the current test data and historical data of each channel at any time. There are two ways to display the corresponding data and curve. It also supports the export of excel report in single or batch form. In addition, it can set the automatic data export after the test according to the needs.

It supports capacity sorting and can grade sort the battery;

The pass / ng results can be judged according to the specified cycle capacity, voltage and time;

Support all kinds of work step protection and global voltage, current and temperature abnormal protection, and carry out abnormal alarm, support battery pack overcharge and over discharge protection test;

Support channel parallel connection (optional according to equipment);

Support unit conversion;

Support database server background storage or MES docking;

Software offline protection;

The software provides free upgrades.

Operating / storage temperature

0℃~40/-10℃~50

Relative humidity of working / storage environment

≤70% RH / ≤ 80% RH (no condensation)

Equipment maintenance

Non professionals are not allowed to open the case. Check the equipment joint regularly to prevent poor contact.