products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13003860308
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
double-side-glove-box
  • Lab Glove Box Lab Double Side Single Box Four Station 800mm Extended Transition Cabin Glove Box

    Lab Double Side Single Box Four Station 800mm Extended Transition Cabin Glove Box A. Acceptance standard: Under standard conditions, that is, under constant temperature of 20-25 oC, relative humidity of 65% and inert air source of 99.999%, the oxygen index of circulating water in empty tank body is less than 0.1ppm.   B. The main technical indicators and configuration 1. Box body 1.1. Size: 1800mm (L) x 900mm (H) x 1000mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Aperture 0.3 micron 1.4. Butyl rubber gloves: original imported from the United States thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Tilted operating surface, 8mm safety tempered glass front window, wear resistance, corrosion resistance, good light transmission, 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure (-10mbar-10mbar) when used. 1.7. The cabinet is equipped with anti-reflection lighting energy-saving lamp, the light is soft. 1.8. The box body is provided with two layers of display board hoisting shelves 1.9. The box is provided with a porous power terminal board (Power supply: 220V±10% 50Hz±10%) 1.10. Three standard KF-40 ports can be configured on the housing. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters. 2. Transition cabin 2.1 Large and small transition bins (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected with glove box, adopt shaft lock large transition door, easy to operate. 2.1.2 Size: large transition cabin with diameter of 360mm and length of 800mm, piston door, transition cabin with sliding tray and polishing, a small transition cabin with size of 150mm in diameter and 300mm in length, air pumping and replenishing controlled by manual valve. 2.1.3. Tray: Freely movable extension (large overcabin configuration) 2.1.4. Vacuum ≤1bar(large and small right transition cabins are required to be vacuumed, with vacuum gauge display) 3. Control system 3.1. Mode: Including self - diagnosis, power off - start feature, with pressure control and self - adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and the transition chamber at a certain set value. a) The user can set the working pressure range between +12.5 and -12.5 mbar at will, and PLC will automatically adjust the pressure of the box within the set range. Default values for operating pressure ranges are -1 to +3 millibars. b) When the case pressure is greater than 12 mbar, PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials in the case. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of glove box, convenient operation. 4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, United States UOP purification material, Germany Baode valve. The host system is integrated with modular design, automatic electronic control air circuit solenoid valve group, PLC control, circuit, circulating pump, purification column, display integrated with an independent purifier, forming a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjusting device: Through PLC touch type adjustment (heating, pumping, purification, regeneration) the whole process except 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulating fan: 0-100m³ high speed frequency conversion fan, microprocessor controlled, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material German BASF deoxygenation material 5kg, the United States UOP highly efficient water absorption material 5kg, extremely high life, to ensure that the user in the use of the product purification capacity long lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: H13 high efficiency filter with 0.3 micron aperture screen conforming to HEPA standard. 4.9. Regeneration: used to reuse the purification system and activate it; Regeneration requires a mixture of helium /H2, nitrogen /H2, or argon /H2, with H2 accounting for 10%. 5. Display system SIEMENS, Germany, unit control using Siemens PLC touch screen. Both Chinese and English can be switched. 6. Water analyzer, (imported from abroad) brand material: British MICHELL/ (according to customer use environment decision) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's Settings to achieve circulation drop. 5) Environment: -10℃ -- 50℃ 7. Oxygen analyzer, (imported from abroad) brand materials: AVCRAY (in accordance with the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000ppm 2) Environment: -10℃ -- 50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. Regardless of gas circulation or not, the oxygen sensor can continuously detect the atmosphere in the box and display the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are accurate zero, small drift, avoid other battery materials easy to be corroded; Low replacement cost (only oxygen battery replacement). 6) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic circulation function to maintain the oxygen content in the glove compartment within the user's specified range. 8. Vacuum system Added vacuum pump start-stop time control. Edwards vacuum pump, model RV12, flow 12m3/h, limit vacuum 2x10-3 millibar. The transition chamber can be vacuumed separately and can be controlled separately at any time. (imported from abroad) 9. Box body automatic cleaning Automatic gas-controlled electroplating plate; The user sets the cleaning time, then touch the start button on the touch screen, the system will start cleaning the box, and automatically stop when the set time. 10. Organic solvent adsorption system To prevent the effect of organic solvent on the purifying column, a solvent column is connected in series to the glove box system. The medium is mainly high quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG. There are KF40 interfaces on the top and bottom of the column, which is convenient for refueling. Users can refueling by themselves. 11. Working conditions of the equipment: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory should have an independent ground wire: < 3Ω, from the equipment to the ground wire connection is recommended to use ≥10mm2 flat copper wire; 1.2. Water supply: None; 1.3. Relative humidity: < 75%; 1.4. There is no large amount of dust, corrosive, flammable and explosive gas in the room; 1.5. Equipment covers area: Length × width :3200mm× 1200mm C. Main configuration No Configuration Unit Qty Manufacturer/brand Remarks 1 Glove box Pcs 2 TMAXCN 304 stainless steel thickness 3mm 2 Transition chamber Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc Import assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, United States UOP purification material, Germany Baode valve Import assembly 5 Display system Set 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe joint Set 1 French Rocole(France) Import 8 Pressure gauge Set 2 WIka(Germany) Import 9 PLC water analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN 304 stainless steel   The partial extension of the transition module can refer to this drawing (reference only for the transition module part).      

  • Double Side Glove Box Four Station Double Box Double Side 800mm Extended Cabin Glove Box

    Four Station Double Box Double Side 800mm Extended Cabin Glove Box A. Acceptance standard: Under standard conditions, that is, under constant temperature of 20-25 oC, relative humidity of 65% and inert air source of 99.999%, the oxygen index of circulating water in empty tank body is less than 0.1ppm. B. The main technical indicators and configuration 1. Box body 1.1. Size: 2400mm (L) x 900mm (H) x 1000mm (W). 1.2. Material: stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Aperture 0.3 micron 1.4. Butyl rubber gloves: original imported from the United States thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Tilted operating surface, 8mm safety tempered glass front window, wear resistance, corrosion resistance, good light transmission, 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure (-10mbar-10mbar) when used. 1.7. The cabinet is equipped with anti-reflection lighting energy-saving lamp, the light is soft. 1.8. The box body is provided with two layers of display board hoisting shelves 1.9. The box is provided with a porous power terminal board (Power supply: 220V±10% 50Hz±10%) 1.10. Three standard KF-40 ports can be configured on the housing. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, including casters 950 mm high, installed with universal casters. 2. Transition cabin 2.1 Large and small transition cabins (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected with glove box, adopt shaft lock large transition door, easy to operate. 2.1.2 Size: large transition cabin with diameter of 360mm and length of 800mm, piston door, transition cabin with sliding tray and polishing, a small transition cabin with size of 150mm in diameter and 300mm in length, air pumping and replenishing controlled by manual valve. 2.1.3. Tray: Freely movable extension (large overcabin configuration) 2.1.4. Vacuum ≤1bar(large and small right transition cabins are required to be vacuumed, with vacuum gauge display) 3. Control system 3.1. Mode: Including self - diagnosis, power off - start feature, with pressure control and self - adaptive function. Automatic control, cycle control, password protection, vacuum chamber control using LCD display. Unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and the transition chamber at a certain set value. a) The user can set the working pressure range between +12.5 and -12.5 mbar at will, and PLC will automatically adjust the pressure of the box within the set range. Default values for operating pressure ranges are -1 to +3 millibars. b) When the case pressure is greater than 12 mbar, PLC will automatically open the safety valve to relieve pressure and protect gloves, equipment and materials in the case. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of glove box, convenient operation. 4. Circulation system (including purification and regeneration system) 4.1. Germany BASF, United States UOP purification material, Germany Baode valve. The host system is integrated with modular design, automatic electronic control air circuit solenoid valve group, PLC control, circuit, circulating pump, purification column, display integrated with an independent purifier, forming a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjusting device: Through PLC touch type adjustment (heating, pumping, purification, regeneration) the whole process except 2.5 hours of ventilation without human monitoring. 4.4. Working gas: He.N2/ or Ar gas (gas cycle) 4.5. Circulating fan: 0-100m³ high speed frequency conversion fan, microprocessor controlled, pressure tested stainless steel device. 4.6. Purification column: single purification column, imported purification material German BASF deoxygenation material 5kg, the United States UOP highly efficient water absorption material 5kg, extremely high life, to ensure that the user in the use of the product purification capacity long lasting. Water removal capacity 2.2㎏ oxygen absorption capacity 63L. 4.7. Purification valve: automatic electro-pneumatic valve. 4.8. Filter: H13 high efficiency filter with 0.3 micron aperture screen conforming to HEPA standard. 4.9. Regeneration: used to reuse the purification system and activate it; Regeneration requires a mixture of helium /H2, nitrogen /H2, or argon /H2, with H2 accounting for 10%. 5. Display system SIEMENS, Germany, unit control using Siemens PLC touch screen. Both Chinese and English can be switched. 6. Water analyzer, (imported from abroad) brand material: British MICHELL/ (according to customer use environment decision) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's Settings to achieve circulation drop. 5) Environment: -10℃ -- 50℃ 7. Oxygen analyzer, (imported from abroad) brand materials: AVCRAY (in accordance with the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measurement range can be set: 0-1000ppm 2) Environment: -10℃ -- 50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. Regardless of gas circulation or not, the oxygen sensor can continuously detect the atmosphere in the box and display the oxygen content in the glove box. 5) Sensor: electrochemical material battery, its advantages are accurate zero, small drift, avoid other battery materials easy to be corroded; Low replacement cost (only oxygen battery replacement). 6) Display: The output of the analyzer is connected to PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can choose the automatic circulation function to maintain the oxygen content in the glove compartment within the user's specified range. 8. Vacuum system Added vacuum pump start-stop time control. Edwards vacuum pump, model RV12, flow 12m3/h, limit vacuum 2x10-3 millibar. The transition cabinr can be vacuumed separately and can be controlled separately at any time. (imported from abroad) 9. Box body automatic cleaning Automatic gas-controlled electroplating plate; The user sets the cleaning time, then touch the start button on the touch screen, the system will start cleaning the box, and automatically stop when the set time. 10. Organic solvent adsorption system To prevent the effect of organic solvent on the purifying column, a solvent column is connected in series to the glove box system. The medium is mainly high quality and efficient activated carbon and activated alumina to prevent the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG. There are KF40 interfaces on the top and bottom of the column, which is convenient for refueling. Users can refueling by themselves. 11. Working conditions of the equipment: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory should have an independent ground wire: < 3Ω, from the equipment to the ground wire connection is recommended to use ≥10mm2 flat copper wire; 1.2. Water supply: None; 1.3. Relative humidity: < 75%; 1.4. There is no large amount of dust, corrosive, flammable and explosive gas in the room; 1.5. Equipment covers area: Length × width :3200mm× 1200mm   C. Main configuration No Configuration Unit Qty Manufacturer/brand Remarks 1 Glove box Pcs 2 TMAXCN 304 stainless steel thickness 3mm 2 Transition cabin Set 1 TMAXCN 304 stainless steel 3 Control system Set 1 Germany SIEMENS Omron electronic devices, etc Import assembly 4 Circulation system (including purification and regeneration system) Set 1 Germany BASF, United States UOP purification material, Germany Baode valve Import assembly 5 Display system Set 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe joint Set 1 French Rocole(France) Import 8 Pressure gauge Set 2 WIka(Germany) Import 9 PLC water analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Set 1 TMAXCN 304 stainless steel   The partial extension of the transition module can refer to this drawing (reference only for the transition module part).    

  • Lab2000 Glove Box Lab2000 Four Station Double Side Transition Cabin Glove Box with Siemens PLC Touch Screen

    Lab2000 Four Station Double Side Transition Cabin Glove Box with Siemens PLC Touch Screen I. Acceptance criteria: Under standard conditions, that is, constant temperature of 20-25 oC, relative humidity of 65%, and inert gas source of 99.999%, the circulating water and oxygen indexes of the empty box are all less than 0.1ppm.   II.Main technical indicators and configuration 1. Box 1.1. Dimensions: 1800mm (length) × 900mm (height) × 1000mm (width). 1.2. Material: All stainless steel structure (Type 304), thickness 3mm. 1.3. Filter: Pore size 0.3 microns 1.4. Butyl rubber gloves: imported from the United States, thickness 0.4mm, glove mouth 8 inches, POM glove mouth, caliber 220mm. 1.5. Window: Operation surface with inclined design, 8mm safety tempered glass front window, wear-resistant, anti-corrosion, good light transmission, the sealing ring adopts 3/8 inch thick OMEGA sealing ring. 1.6. It can maintain a certain positive and negative pressure during use (-10mbar-10mbar) 1.7. The box is equipped with anti-reflection lighting energy-saving lamps, and the light is soft. 1.8. The box is equipped with a display board and a 2-layer hanging rack 1.9. There is a multi-hole power terminal board in the box (power supply: 220V±10% 50Hz±10%) 1.10. The cabinet can be set with 3 standard KF-40 ports. 1.11. Leakage rate: ≤0.001vol%/h. 1.12. Steel structure bracket, height 950 mm including casters, installed with swivel casters. 2. Transition cabin 2.1 Large and small transition warehouse (right side) 2.1.1 Shape: Cylindrical (304 stainless steel), connected to the glove box, with a shaft-lock type large transition hatch, which is easy to operate. 2.1.2 Dimensions: diameter 390mm, length 600mm large transition cabin, piston door, sliding tray in the transition cabin, polished, another small transition cabin in the box, specifications: diameter 150mm, length 300mm, manual valve control air extraction and tonic. 2.1.3. Tray: free to move and extend (large transition cabin configuration) 2.1.4. Vacuum degree ≤ 1bar (both large and small right transition cabins are required to be evacuated with display) 3. Control system 3.1. Mode: including self-diagnosis, self-starting characteristics after power failure, with pressure control and self-adaptive functions. LCD display is used for automatic control, cycle control, password protection and vacuum chamber control. The unit control adopts Siemens PLC touch screen. 3.2. Pressure control: control the pressure of the box and transition cabin at a certain set value. a) The user can arbitrarily set the working pressure range between +12.5 and -12.5 mbar, and the PLC will automatically adjust the box pressure within the set range. The default value for the working pressure range is -1 to +3 mbar. b) When the box pressure is greater than 12 mbar, the PLC will automatically open the safety valve to release the pressure to protect the gloves, equipment and materials in the box. c) Use the foot switch to fine-tune the tank pressure. 3.3. Foot pedal: can control the pressure of the glove box, easy to operate. 4. Circulation system (including purification and regeneration system) 4.1. German BASF, American UOP purification material, German Baode valve. The host system integrates modular design, fully automatic electronically controlled gas circuit solenoid valve group, PLC control, circuit, circulating pump, purification, and display integrates an independent purifier to form a compact and simple system. 4.2. Control: Water and oxygen are controlled at less than 1PPm 4.3. Adjustment device: through PLC touch adjustment (heating, evacuation, purification, regeneration), the whole process does not require human monitoring except for 2.5 hours of ventilation. 4.4. Working gas: He.N2/or Ar gas (gas circulation) 4.5. Circulation fan: 0-100m³ high-speed variable frequency fan, microprocessor controlled, stainless steel device that has been pressure tested. 4.6. Purification column: single purification column, imported purification material German BASF deaerator material 5kg, American UOP high-efficiency water absorbing material 5kg, extremely high lifespan, ensuring long-lasting purification ability of the product during use. The water removal capacity is 2.2㎏ and the oxygen absorption capacity is 63L. 4.7. Purge valve: fully automatic electric valve. 4.8. Filter: H13 high-efficiency filter with 0.3 micron pore size filter mesh that meets HEPA standard. 4.9. Regeneration: It is used to re-use and activate the purification system; regeneration requires a mixture of helium/H2, nitrogen/H2 or argon/H2, of which H2 accounts for 10%. 5. Display system Germany SIEMENS, the unit control adopts Siemens PLC touch screen. Chinese and English bilingual can be switched. 6. Water analyzer, (imported from abroad) Brand material: British MICHELL / (according to the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) Measuring range: 0-1000ppm 2) Accuracy: ±1% ppm 3) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. 4) Control: The gas circulation system can be controlled according to the user's setting to realize the circulation drop. 5) Environment: -10℃-50℃ 7. Oxygen analyzer, (imported from abroad) Brand material: American AVCRAY (according to the customer's use environment) non-domestic or domestic assembly, third-party data to ensure credibility. 1) The measurement range can be set: 0-1000, ppm 2) Environment: -10℃-50℃ 3) Accuracy: ±1% ppm 4) Installation position: The oxygen sensor is installed on the box. No matter whether the gas is circulating or not, the oxygen sensor continuously detects the atmosphere in the box and displays the oxygen content in the glove box. 5) Sensor: Electrochemical material battery, which has the advantages of accurate zero point, small drift, avoiding the easy corrosion of other battery materials; low replacement cost (only oxygen battery is replaced). 6) Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen, and the alarm value can be set. Control: The user can select the automatic cycle function to maintain the oxygen content in the glove box within the user's specified range. 8. Vacuum system Increase the vacuum pump start and stop time control. The vacuum pump is a British Edwards vacuum pump, model RV12, with a flow rate of 12m3/h and an ultimate vacuum of 2x10-3 mbar. The transition cabin can be evacuated separately, and can be controlled independently at any time. (imported from abroad) 9. Automatic cleaning of the box Automatic gas control electroplating board; the gas in the box is automatically cleaned by the user to set the cleaning time, and then touch the start button on the touch screen, the system will start cleaning the box, and it will automatically stop when the set time is reached. 10. Organic solvent adsorption system In order to prevent the influence of organic solvents on the purification column, a solvent column is connected in series to the glove box system. The media are mainly high-quality and high-efficiency activated carbon and activated alumina that prevents the formation of hydrofluoric acid. The filling capacity of the organic solvent adsorption system is 7KG, and there are KF40 interfaces on the top and bottom of the column, which is convenient for material change, and users can change the material by themselves. 11. Equipment working conditions: (provided by the user) 1.0. Power supply: two-phase three-wire AC220V, power ≥1Kw; 1.1. The laboratory must have an independent ground wire: <3Ω, it is recommended to use a flat copper wire of ≥10mm2 for the connection from the equipment to the ground wire; 1.2. Water supply: none; 1.3. Relative humidity: <75%; 1.4. There is no large amount of dust in the room, no corrosive, flammable and explosive gas; 1.5. Equipment area: length × width: 3200mm × 1200mm   III.Main configuration No Configure Unit Qty Manufacturer/Brand Remark 1 Box Pcs 1 TMAXCN 304 stainless steel thickness 3mm 2 Transition cabin Pcs 1 TMAXCN 304 stainless steel 3 Control System Pcs 1 Germany SIEMENS Omron electronic devices, etc. Import assembly 4 Circulation system (including purification and regeneration system) Pcs 1 German BASF, American UOP purification material, German Baode valve Import assembly 5 Display system Pcs 1 SIEMENS(Germany) Import 6 Gloves Pair 4 United States Import 7 Pipe interface Pcs 1 French Rocole(France) Import 8 Pressure gauge Pcs 2 WIka(Germany) Import 9 PLC Water Analyzer Pcs 1 Michell(UK) Import 10 PLC oxygen analyzer Pcs 1 AVCRAY(USA) Import 11 Vacuum pump Pcs 1 RV12 Import 12 Organic solvent adsorption Pcs 1 TMAXCN 304 stainless steel        

Go To Page