products categories

contact us

  • If you have questions, please contact us, all questions will be answered
  • WhatsApp : +86 13174506016
  • Email : David@tmaxcn.com
  • Email : Davidtmaxcn@gmail.com
  • Add : No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)
products
30L Planetary Vacuum Mixer

30L Vacuum Planetary Mixing Machine for Battery Slurry & High-Viscosity Materials

  • Model Number:

    TMAX-JBT-30L
  • Compliance:

    CE Certified
  • Warranty:

    One years limited warranty with lifetime technical support
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    60 days
Product Details

30L Vacuum Planetary Mixing Machine for Battery Slurry & High-Viscosity Materials



Ⅰ. Equipment Features:

Applicable Scope

Once the mixer finishes preparing the slurry, tilt the 30 L bucket onto the elevator and attach the mixing head to convert it into a slurry transfer tank. This setup allows for the transfer of slurry from the mixing room to the storage and coating areas. The slurry is then delivered to the main tank or coating head through conversion fittings.

 

Ⅱ. Main Technical Parameters:

Container Parameters

Design total volume: 45 L

Effective volume: 15–30 L

Container inner diameter: 400 mm

Container inner depth: 360 mm

Contact material: SS 304

Temperature-jacket configuration: single-layer jacket on tank wall for heating/cooling; single-layer jacket on bottom for heating/cooling

Jacket connection: G 1/2″ quick-connect union, rated ≤0.4 MPa

Jacket circulation: customer-supplied; inlet water ≤8 °C, flow >15 L/min

Discharge port: one G 1″ three-piece ball valve at bottom; with 1″ standard ISO quick clamp

Operating ambient temperature: –10 °C to +120 °C

Mobility: mounted on casters

Interchangeable with 30 L mixer bucket

 

Mixing Components

Operating frequency: 50 Hz

Mixing power: 0.75 kW (one unit)

Mixing speed: 48 rpm (fixed)

Impeller diameter: 380 mm

Impeller type: inclined-paddle spiral

Impeller material: SS 304

Impeller tip speed: 1.0 m/s

Number of impellers: 1

Number of shafts: 1

Clearance from impeller to tank wall: 10 mm

Clearance from impeller to tank bottom: 8 mm

Principle: unique inclined-paddle design prevents material sedimentation

 

Top Lid Components

Lid material: SS 304

Feed inlet: one ISO standard 1″ quick-connect

Viewing ports: two DN50 tempered-glass sight glasses

Vacuum module: one set with G 3/4″ connections (vacuum and vent)

Mechanical vacuum gauge port: one Y60 mechanical gauge

 

Control System

Electrical cabinet: houses inverter and low-voltage components

Manual control panel: includes buttons, knobs, instruments

Power supply: AC 3×380 V ±5%, 50 Hz

Control method: electrical control

Operation: button + knob panel on electrical cabinet

Emergency stop: one button

Start button: one

Stop button: one

Worklight switch: one

 

Safety Interlock System

Emergency stop: pushes E-stop, machine halts immediately; no further operation

 

Other Notes

Oil seals: domestic brand; static seal by O-ring, dynamic by mechanical or skeleton seal

Lubricant grease: domestic

Valves: domestic

Vacuum requirements: customer-supplied vacuum system at 8 L/s (2×8)

Vacuum retention: –0.098 MPa, must hold >–0.085 MPa for 24 h without leakage

Main power: >1 kW

Total weight: approx. 250 kg

Dimensions: L 594 mm × W 560 mm × H 1420 mm

Color: off-white

Load-bearing floor: 400 kg/m²

 

Ⅲ. List of Randomly Supplied Wear Parts:

No.

Name

Specification

Material

Quantity

Remarks

1

Lid sealing Oring

ΦD×ΦN

Silicone

1

Matches model; per supplier’s standard

2

Sight-glass sealing Oring

Silicone

2

Matches model; per supplier’s standard

3

Feed port sealing gasket

Silicone

1

Matches model; per supplier’s standard

4

Sight-glass pane

tempered

Glass

2 pcs

Matches model; per supplier’s standard

 

Ⅳ. Supporting Conditions:

No.

Item

Requirement

5

Workshop Height

> 3.0 m; allows lifting for maintenance; floor clean and level

6

Door Opening

Height > 2.0 m; Width > 1.5 m; ensures machine transport

7

Cooling Water

Ensure cooling; ideally with forced supply; in winter, provide hot water

8

Heating

In cold climates, maintain room > 20 °C so hydraulic oil does not solidify; ensures smooth lifting and lubrication

9

Installation Space

Arrange per layout drawings

10

Air Supply

5–7 kgf/cm², 50 L/min; for pneumatic pumps etc.

11

Others

No corrosive or explosive gases/liquids