products
vacuum glove box

Glove Box with H2O and O2 Purification System as lithium ion battery lab machine

  • Model Number:

    TMAX-GB-D1
  • Dimension(L*W*H):

    1220*750*900mm
  • Compliance:

    CE Certified
  • Warranty:

    One years limited warranty with lifetime technical
  • MOQ:

    1
  • Payment:

    L/C D/A D/P T/T Western Union
  • Delivery Time:

    10 day
  • contact now
Product Details

Glove Box with H2O and O2 Purification System as lithium ion battery lab machine

 Single purification unit, PLC control and touch screen operation system. under standard conditions, a standard atmospheric pressure, relative humidity 65%, 99.999% of inert gas source, water oxygen index less than 1 PPM.

 

Functions

1,Closed recirculation: Inert gas recirculate through circulating fan and purifier in the glove box,get rid of water and oxygen continuously.

2,automatic regeneration control:the materials used for getting rid of water and oxygen can be regenerated by program control.

3,automatic cleaning:The replacement of the gas in the glove box is controlled by cleaning valves.

4,The pressure in the box is controlled by PLC.It can be free set within +/-10mbar.If overtop +/-12mbar,automatic protection will start.

5,Vacuum pump will start automatically when the system required.

SPECIFICATIONS:

Model

TMAX-GB-D1

Source voltage 

AC110V-240V, Customized

Warranty

One Year limited warranty with lifetime support

Type

Single section single station

Dimension(L*W*H)

SUS304 stainless steel plate, 1200*800*930mm

Total dimension(L*W*H)

SUS304 stainless steel plate, 1915*830*1830mm

Big transitive cabin

SUS304 stainless steel, DN385*588mm

Small transitive cabin

SUS304 stainless steel, DN150*350mm 

Gloves 

2 pcs, butyl material, thickness : 0.4mm

Gloves port

DN215mm, Acid and alkali resistant material PPS

Purification system

Single purifying column, 

With the remove of water, oxygen function

Control system

6 inch color touch screen, SIEMENS

Vacuum pump

4L/S

Pressure sensor

-2500~2500Pa, Touch screen

H2O concentration 

<1 ppm (20 °C, 1 atm) Touch screen

Oxygen concentration

<1 ppm (20 °C, 1 atm) Touch screen

Organic solvent filter

21 L

Working gas

N2,Ar,He


Specifications of Standard Model of Purification Glove Box

No.

Model No.

Box Dimensions

Total Dimensions

Operating Sides

Numbers of Gloves

Options

1

GBP800S-2

1200*800*930mm

1915*830*1830mm

Single

2

Single or double purification columns

2

GBP1000S-4

1200*1000*930mm

1915*1060*1830mm

Single

4

Single or double purification columns

3

GBP1000D-4

1200*1000*930mm

1915*1060*1830mm

Double

4

Single or double purification columns

4

GBP1200S-2

1200*1200*930mm

1915*1260*1830mm

Single

2

Single or double purification columns

5

GBP1200D-4

1200*1200*930mm

1915*1260*1830mm

Double

4

Single or double purification columns

 

 

 

 

 

 

 

6

GBP800S-3

1500*800*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

7

GBP1000S-3

1500*1000*930mm

2215*1060*1830mm

Single

3

Single or double purification columns

8

GBP1000D-6

1500*1000*930mm

2215*1060*1830mm

Double

6

Single or double purification columns

9

GBP1200S-3

1500*1200*930mm

2215*1260*1830mm

Single

3

Single or double purification columns

10

GBP1200D-6

1500*1200*930mm

2215*1260*1830mm

Double

6

Single or double purification columns

 

 

 

 

 

 

 

11

GBP800S-4

1900*800*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

12

GBP1000S-4

1900*1000*930mm

2615*1060*1830mm

Single

4

Single or double purification columns

13

GBP1000D-8

1900*1000*930mm

2615*1060*1830mm

Double

8

Single or double purification columns

14

GBP1200S-4

1900*1200*930mm

2615*1260*1830mm

Single

4

Single or double purification columns

15

GBP1200D-8

1900*1200*930mm

2615*1260*1830mm

Double

8

Single or double purification columns

Notes
Cabinet water and oxygen content under the standard condition:  
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gases
a) Working Gas: N2
ArHe and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements

 
 

 

 

                  vacuum Glove Box

                    

 

 


1.  We supply machines with battery technology support.

2.  We supply full set of lithium battery equipment for lab research, pilot scale research and production line.


Dry Glove Box

1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

3 Responsible for the damage during the shipping process, will change the damage part for you for free.



 


inquiry now

    We will give you a quotation within 24 hours. give you a quotation within 24 hours.

      Glove Box with H2O and O2 Purification System as lithium ion battery lab machine

    Contact Us:

    Xiamen Tmax Battery Equipments Limited.

    Add:No. 39, Xinchang Road, Xinyang, Haicang Dist., Xiamen, Fujian, China (Mainland)

    Email:[email protected]
    Email:[email protected]
    Skype:[email protected]